top of page
Codi's logo

Low-Voltage Switchboards

PANELBOARD

UL 67 Listed · NEMA 1 / 3R

The CODI UL 67 Panelboard is engineered for branch circuit distribution in commercial, institutional, and light industrial facilities. Configurable for main lugs only (MLO) or main circuit breaker (MCB), each unit is custom-built to your project's voltage, ampacity, phase arrangement, and circuit count — with multi-brand breaker flexibility to match your existing site standards. Unlike off-the-shelf catalog panelboards, CODI builds to your specification, not the other way around. Independently manufactured in Littleton, Colorado with shorter lead times and no proprietary breaker lock-in. Designed for commercial buildings, data centers, and industrial facilities where configurable protection and clean documentation are non-negotiable.

100A–1200A

120/208V–277/480V

65kAIC

Custom UL 67 panelboards for branch circuit distribution in commercial and light industrial facilities. MLO or MCB configurations, multi-brand breaker flexibility, and configurable ampacity. Shorter lead times than national OEMs. Built in Littleton, Colorado.

100A–1200A

120/208V–277/480V

65kAIC

6-10

WEEK LEAD TIME

KEY FEATURES

Custom-Configured Not Catalog

Built to your exact circuit count, voltage, and enclosure rating rather than forcing a standard catalog size that leaves capacity unused or falls short.

Multi-Brand Breaker Flexibility

Accepts branch breakers from Eaton, Siemens, ABB, LS Electric, and Schneider to match your facility standard or existing infrastructure.

UL 67 Listed

Factory-tested and UL 67 listed. Ships with a complete documentation package including wiring diagrams, BOM, and UL label.

Full NEMA Enclosure Range

Available in NEMA 1, 3R, 4, and 4X ratings to meet indoor, outdoor, washdown, and corrosive environment requirements.

Colorado Built — Shorter Lead Times

Manufactured in Littleton, CO with 30+ years of fabrication experience. Custom configurations without the lead times of national OEMs.

No Proprietary Lock-In

You specify the breaker brand at the time of order. No forced substitutions and no downstream service dependency on a single manufacturer.

FULL SPECIFICATIONS

    • UL 67: Panelboards 

    • NFPA 70 (NEC) Article 408: Compliant for Panelboard construction and wire bending space

    • NEC 408.36: Overcurrent protection requirements for panelboards

    • NEC 230.70 / 230.91: Service equipment requirements when configured as service entrance

    • Service Entrance (SE): Suitable for use as service equipment when specified per NEC 230

    • Voltage: 120/208V, 277/480V, 347/600V; single-phase and three-phase configurations available 

    • Ampacity: Main ratings from 100A to 1200A 

    • Short-Circuit Current Rating (SCCR): Standard 65kAIC; higher ratings available with current-limiting fuses or high-SCCR breakers 

    • Phases: 1-phase 2-wire; 1-phase 3-wire; 3-phase 3-wire; 3-phase 4-wire 

    • Branch Circuits: Up to 42 circuits standard; higher counts available

    • Enclosure Material: Heavy-gauge steel with powder-coat finish 

    • Bus: Silver-plated copper main and distribution bus; fully-rated bus standard 

    • Main Device: Main lugs only (MLO) or main circuit breaker (MCB) configurations available 

    • Branch Spaces: Top-feed or bottom-feed provisions; surface or flush-mount options 

    • Finish: Powder-coated standard; custom colors available

    • Main Protective Device: Molded-case circuit breaker or main lugs per specification 

    • Branch Breakers: 1-pole, 2-pole, or 3-pole circuit breakers from major manufacturers (Siemens, Eaton, etc.) 

    • Neutral Bar: Full-capacity silver-plated neutral bar with individual terminal lugs 

    • Ground Bar: Isolated or bonded ground bar as required by application 

    • Surge Protection: Type 1 or Type 2 SPD available for downstream electronics protection

    • Dead-Front Design: Interior dead-front panel prevents accidental contact with live bus and breakers during operation 

    • Grounding: Dedicated ground bus bonded to enclosure per NEC requirements 

    • Overcurrent Protection: Branch circuit breakers provide coordinated short-circuit and overload protection 

    • Arc-Flash: Panelboard configuration and documentation support arc-flash analysis per NFPA 70E 

    • Locking: Panelboard cover latch and optional padlockable trim for secured access

    • Custom Configuration: Built to your project's voltage, ampacity, phase arrangement, and circuit count — not a catalog substitute.

    • UL 67 Listed: Every panelboard ships UL 67 listed for reliable branch circuit distribution in commercial and light industrial applications.

    • MLO or MCB Options: Available in main lug only or main circuit breaker configurations to match your project's service entrance and distribution requirements.

    • Multi-Brand Breaker Compatibility: Accommodates 1-pole, 2-pole, and 3-pole circuit breakers from major manufacturers (Siemens, Eaton, etc.) — no proprietary lock-in.

    • Wide Voltage Range: Configurable for 120/240V, 120/208V, 277/480V, and 347/600V systems; single-phase and three-phase AC configurations, 125VDC and 250VDC options also available.

    • High-Capacity Branch Circuits: Standard configurations up to 42 circuits; higher circuit counts available for large distribution applications.

    • Full-Capacity Neutral Bus: Silver-plated copper neutral bus with individual terminal lugs; 100% rated neutral available.

    • Service Entrance Ready: Optional Service Entrance (SE) rating allows the unit to serve as the primary disconnect per NEC 230.

    • Surge Protection: Type 1 or Type 2 Surge Protective Devices (SPD) available to protect sensitive downstream electronics.

    • Dead-Front Construction: Internal dead-front panel prevents accidental contact with live bus and branch breakers during operation.

    • Enclosure Options: TYPE 1 (indoor) and TYPE 3R (outdoor) configurations available.

    • MADE IN THE USA: Engineered and assembled in Littleton, Colorado for faster lead times and direct manufacturer support.

RESOURCES

this section will be built out once we have more documentation.
Future: test case studies
this section will be built out once we have more documentation.

VIDEO

BUILT THE CODI WAY

STRUCTURAL ENGINEERING

  • Hex-Formed Corners

  • Powder coating in any color

  • Internal cable routing pathways

  • Tab & slot nest together precisely

MANUFACTURING EXCELLENCE

  • Shorter lead-times than national OEMs

  • Ships right the first time

  • 30 years of fabrication experience

  • 100k sq.ft. Littleton, CO facility

OEM BREAKER FLEXIBILITY

  • Matches your existing infrastructure specs

  • No proprietary lock-in

  • Access to multiple OEM breaker brands

STREAMLINED ORDER PROCESS

  • Online configuration tool

  • Quotes reviewed in-house typically within 1 business day 

READY TO SPEC YOUR PANELBOARD?

EXPLORE OTHER PRODUCTS