top of page
CODI Power Controls Logo
CONTACT US

Low-voltage · Dead-front

SWITCHBOARDS · UL 891

Custom service-entrance and main distribution switchboards for industrial and critical facilities.

Each dead-front switchboard is engineered around your voltage, ampacity, fault current, breaker standard and enclosure rating, then built and tested in Littleton, Colorado.

UL Certified Badge

UL File Number

E543445

Ampacity

400A–5000A

SCCR

65–200kAIC

SPECIFICATIONS

COMPLIANCE

  • Applicable Standard: UL 891 - Dead-Front Switchboards 

  • Applicable Codes: NEC (ANSI/NFPA 70); CSA C22.2 No. 244 (Canada, when applicable) 

  • Maximum Voltage Rating: Up to 600 V AC nominal (maximum 1,000 V within UL scope) 

  • Intended Application: Commercial and Light Industrial Power Distribution

RATINGS

  • Input Voltages Available: 120/208 V, 240 V, 480/277 V, 600/347 V AC 

  • Frequency: 60 Hz 

  • Main Bus Ampere Rating: 400 A - 5,000 A (higher ratings available by design) 

  • Short-Circuit Current Rating (SCCR): Up to 200 kAIC at specified voltage 

  • Short-Time Withstand: 3-cycle withstand (0.05 seconds)

CONSTRUCTION/BUILD

  • Construction: Dead-front per UL 891

  • Enclosure: Galvannealed steel with powder-coat or stainless steel finish

  • Rating: NEMA 1 (indoor) and NEMA 3R (outdoor)

  • Seismic: Available with bracing to meet project-specific requirements per IBC 1613 and ASCE 7

  • Mounting: Free-standing configurations standard; wall-mount availability dependent on ampacity and breaker frame size

  • Access: Padlockable front doors with three-point latching

  • Cable Entry: Removable gland plates and bottom-feed provisions for conduit routing and cable termination

  • Bus: High-conductivity silver-plated copper or tin-plated aluminum; fully rated neutral and ground bus options available

COMPONENTS

  • Protective Devices: Molded-case or insulated-case circuit breakers

SAFETY

  • SCCR: Rated and marked per UL 891 to project-specific short circuit current requirements

  • Trip Settings: LSI and LSIG configurations available

  • Arc-Flash Risk Reduction: Energy-reducing maintenance settings per NFPA 70 240.87; compatible with AERMS, DAS (Siemens), and RELT (ABB)

  • Zone-Selective Interlocking: Available where applicable

  • Ground Fault Protection: Per NFPA 70B

  • Thermal Inspection: Compliance-ready designs for routine infrared inspection

Already have your spec?

CONFIGURE TO SPECS

KEY FEATURES

Custom Configuration

Built to your voltage, ampacity, fault current and breaker requirements.

UL 891 Listed Dead-Front

Ships UL 891 listed. Dead-front design keeps live bus and components out of reach during normal operation.

High-Capacity Bus

400A to 5000A main bus. Silver-plated copper or tin-plated aluminum.

High Fault Current Ratings

SCCR from 65kAIC standard up to 200kAIC.

5 Breaker Brands

Eaton, Siemens, ABB, LS or Schneider Electric.

Enclosure Options

Type 1 indoor or Type 3R outdoor. Stainless steel for corrosive environments.

Why CODI

BUILT THE CODI WAY

We’re lean and nimble by design, and your order is made by people who sincerely care about quality. 

Engineers who understand the build

Engineer at work2

Our engineers don’t hand off drawings and walk away. They’re hands-on in the shop, so their designs work in the real world.

Tough specs

welcome here

Engineer Building Equipment

We aren’t a “sales” organization. You talk to the people who build your order, and special orders don’t scare us.

Accountability at

every step

CODI MFG 8-26-2025-9_edited.jpg

Fabrication, copper bus, assembly and testing, all in-house. Every step has a person who owns it.

Built in America

since 1992

IMG_0594_edited.jpg

Our new 100,000 sq ft facility in Littleton, Colorado, backed by more than three decades of precision manufacturing.

FAQ

What is a UL 891 dead-front switchboard?

A UL 891 switchboard is a low-voltage power distribution assembly listed under the UL 891 standard for dead-front switchboards. Dead-front construction means internal barriers prevent accidental contact with live busbars and components during normal operation or maintenance access. CODI switchboards are factory-tested and ship with a full documentation package including wiring diagrams, bill of materials, and UL label.

How does a switchboard differ from a panelboard?

Switchboards are generally larger, higher-capacity assemblies designed for service entrance and main distribution at the top of a building's electrical hierarchy. They are built to UL 891 and typically handle 400A to 5000A. Panelboards are downstream distribution equipment, typically 100A to 1200A, built to UL 67, and used to distribute branch-circuit power to individual loads. In most facilities, power flows from the utility through a switchboard and then to panelboards.

What short circuit current ratings (SCCR) are available?

CODI switchboards are standard at 65kAIC bracing with options available up to 200kAIC to match facility fault current requirements. SCCR is rated and marked per UL 891. Arc-flash risk reduction configurations are available, including energy-reducing maintenance settings per NEC 240.87 and compatibility with Siemens DAS and ABB RELT systems.

Can CODI switchboards serve as the service entrance for a facility?

Yes. CODI switchboards are available with optional Service Entrance (SE) rating, which allows the unit to function as the primary disconnect point per NEC 230. This is specified at the time of order and requires the appropriate main disconnect device and labeling per NEC 230.70 and 230.91.

Start your order here

CONFIGURE ONLINE

BUILD to specs : ratings, enclosure, bus, and connection options, assembled into a unit matched to your project requirements. This information is what we use to provide a budgetary quote.

CONFIGURE TO SPECS

EMAIL or TALK LIVE

TALK with a CODI engineer who knows power controls, your application, and your constraints. Share the details, and we’ll tell you directly whether CODI has a solution that fits.

CONTACT ENGINEERING

RELATED PRODUCTS

UL 891 generator docking station with quick-connect cam-lock terminals

Permanent connection points for temporary generator power at commercial, industrial and critical facilities.

GO TO PRODUCT
UL 67 low-voltage branch-circuit electrical distribution panelboard

Custom branch-circuit panelboards for commercial, institutional and industrial facilities.

GO TO PRODUCT
bottom of page