Temporary Generator Connection

GENERATOR DOCKING STATIONS

Dual Purpose Docking Station | Load Bank Docking Station

The CODI Generator Docking Station is a UL 891-listed dead-front switchboard engineered as a permanent connection point for temporary generator access. Built for critical power projects, each unit is configured around the site’s voltage, amperage, available fault current, connection type, enclosure rating, interlocking, metering, and project-specific safety options. Designed and assembled in Littleton, Colorado.


UL 891 Listed 

Type 1 / 3R

Customized to your specs

10-12

WEEK LEAD TIME

KEY FEATURES

Universal Breaker Compatibility

Flexible design accommodates power breakers from multiple major manufacturers (Eaton, Siemens, ABB, LS, etc.) to meet specific site requirements.

Rapid Deployment

Features industry-standard Cam-Lock connectors for quick, fail-safe generator hookups during emergencies.

Code-Compliant Safety

Built to UL891 Dead-Front Switchboard standards, ensuring a safe, serviceable, and code-compliant connection point.

Phase Rotation Protection

Phase rotation monitoring ensures safe synchronization with facility power systems.

Rugged Construction

Available in TYPE 1 (Indoor), TYPE 3R (Outdoor), and TYPE 3R (Stainless) configurations to withstand harsh environmental conditions.

Safety Interlocking

Options for Kirk Key or mechanical interlocks to prevent cross-connection and ensure safe transfer sequences between utility and generator power.

FULL SPECIFICATIONS

    • UL 891: Dead-Front Switchboards 

    • NFPA 70 (NEC) Article 408: Compliant for Switchboard construction and wire bending space

    • NEC 700.3(F) & 701.12(G): Meets requirements for temporary generator connection means in Emergency and Legally Required Standby systems

    • NEC 406.13: Design supports safe use of Single-Pole Separable Interconnects (Cam-Locks)

    • Service Entrance (SE): Suitable for use as Service Equipment when specified (per NEC 230)

    • Configurations to comply with NFPA 110 section 8.4:  Options built for required load bank testing critical systems i.e. hospitals, data centers

    • Voltage: Configurable for 208Y/120V, 480Y/277V, and 600V 3-Phase AC systems

    • Ampacity: Available in continuous current ratings from 400A to 4000A

    • Short Circuit Current Rating (SCCR): Standard 65kAIC bracing; options available up to 100kAIC to match facility fault current requirements

    • Environmental: TYPE 3R (Outdoor) rating standard for protection against rain, sleet, and snow; Stainless Steel available for corrosive environments

    • Service Entrance: Optional Service Entrance (SE) rating allows the unit to serve as the primary disconnect point (per NEC 230)

    • Construction: UL 891 dead-front construction

    • Enclosure: Galvannealed steel with powder-coat or stainless steel finish

    • Rating: NEMA 1 (indoor) and NEMA 3R (outdoor)

    • Seismic: Available with bracing to meet project-specific requirements per IBC 1613 and ASCE 7

    • Mounting: Free-standing or wall-mount configurations available depending on ampacity and breaker frame size

    • Access: Padlockable front doors with three-point latching

    • Cable Entry: Removable gland plates and bottom-feed provisions for conduit routing and cable termination

    • Bus: High-conductivity silver-plated copper or tin-plated aluminum; fully rated neutral and ground bus options available

    • Connection Type: Industry-standard Series 16 Cam-Lock receptacles (color-coded to voltage) for rapid, tool-free generator cabling deployment

    • Circuit Breakers: Universal design accommodates power breakers from major manufacturers (Eaton, Siemens, ABB, etc.) to match existing site standards

    • Surge Protection: Integrated Type 1 or Type 2 Surge Protective Devices (SPD) available to shield sensitive downstream electronics from transient voltage spikes

    • Instrumentation: Phase Rotation Monitor and optional Voltage Indicator(s) ensure safe synchronization with facility power systems before connection

    • Interlocking: Kirk Key or mechanical walking-beam interlocks available to prevent cross-connection and ensure safe transfer sequences between utility and generator power

    • Connector Safety: Design supports compliance with NEC 406.13 for Single-Pole Separable Interconnects (Cam-Locks), preventing accidental disconnection under load

    • Dead-Front Design: Internal barriers prevent accidental contact with live busbars during operation or maintenance

    • Grounding: Dedicated grounding studs and fully rated ground bus ensure personnel safety during temporary power setup

RESOURCES

Add a Title
Add a Title
Add a Title

VIDEO

BUILT THE CODI WAY

STRUCTURAL ENGINEERING

  • Hex-Formed Corners

  • Powder coating in any color

  • Internal cable routing pathways

  • Tab & slot nest together precisely

MANUFACTURING EXCELLENCE

  • Shorter lead-times than national OEMs

  • Ships right the first time

  • 30 years of fabrication experience

  • 100k sq.ft. Littleton, CO facility

OEM BREAKER FLEXIBILITY

  • Matches your existing infrastructure specs

  • No proprietary lock-in

  • Access to multiple OEM breaker brands

STREAMLINED ORDER PROCESS

  • Online configuration tool

  • Quotes reviewed in-house typically within 1 business day 