Temporary Generator Connection
GENERATOR DOCKING STATIONS
Dual Purpose Docking Station | Load Bank Docking Station
The CODI Generator Docking Station is a UL 891-listed dead-front switchboard engineered as a permanent connection point for temporary generator access. Built for critical power projects, each unit is configured around the site’s voltage, amperage, available fault current, connection type, enclosure rating, interlocking, metering, and project-specific safety options. Designed and assembled in Littleton, Colorado.
UL 891 Listed
Type 1 / 3R
Customized to your specs
10-12
WEEK LEAD TIME
KEY FEATURES
Universal Breaker Compatibility
Flexible design accommodates power breakers from multiple major manufacturers (Eaton, Siemens, ABB, LS, etc.) to meet specific site requirements.
Rapid Deployment
Features industry-standard Cam-Lock connectors for quick, fail-safe generator hookups during emergencies.
Code-Compliant Safety
Built to UL891 Dead-Front Switchboard standards, ensuring a safe, serviceable, and code-compliant connection point.
Phase Rotation Protection
Phase rotation monitoring ensures safe synchronization with facility power systems.
Rugged Construction
Available in TYPE 1 (Indoor), TYPE 3R (Outdoor), and TYPE 3R (Stainless) configurations to withstand harsh environmental conditions.
Safety Interlocking
Options for Kirk Key or mechanical interlocks to prevent cross-connection and ensure safe transfer sequences between utility and generator power.
FULL SPECIFICATIONS
UL 891: Dead-Front Switchboards
NFPA 70 (NEC) Article 408: Compliant for Switchboard construction and wire bending space
NEC 700.3(F) & 701.12(G): Meets requirements for temporary generator connection means in Emergency and Legally Required Standby systems
NEC 406.13: Design supports safe use of Single-Pole Separable Interconnects (Cam-Locks)
Service Entrance (SE): Suitable for use as Service Equipment when specified (per NEC 230)
Configurations to comply with NFPA 110 section 8.4: Options built for required load bank testing critical systems i.e. hospitals, data centers
Voltage: Configurable for 208Y/120V, 480Y/277V, and 600V 3-Phase AC systems
Ampacity: Available in continuous current ratings from 400A to 4000A
Short Circuit Current Rating (SCCR): Standard 65kAIC bracing; options available up to 100kAIC to match facility fault current requirements
Environmental: TYPE 3R (Outdoor) rating standard for protection against rain, sleet, and snow; Stainless Steel available for corrosive environments
Service Entrance: Optional Service Entrance (SE) rating allows the unit to serve as the primary disconnect point (per NEC 230)
Construction: UL 891 dead-front construction
Enclosure: Galvannealed steel with powder-coat or stainless steel finish
Rating: NEMA 1 (indoor) and NEMA 3R (outdoor)
Seismic: Available with bracing to meet project-specific requirements per IBC 1613 and ASCE 7
Mounting: Free-standing or wall-mount configurations available depending on ampacity and breaker frame size
Access: Padlockable front doors with three-point latching
Cable Entry: Removable gland plates and bottom-feed provisions for conduit routing and cable termination
Bus: High-conductivity silver-plated copper or tin-plated aluminum; fully rated neutral and ground bus options available
Connection Type: Industry-standard Series 16 Cam-Lock receptacles (color-coded to voltage) for rapid, tool-free generator cabling deployment
Circuit Breakers: Universal design accommodates power breakers from major manufacturers (Eaton, Siemens, ABB, etc.) to match existing site standards
Surge Protection: Integrated Type 1 or Type 2 Surge Protective Devices (SPD) available to shield sensitive downstream electronics from transient voltage spikes
Instrumentation: Phase Rotation Monitor and optional Voltage Indicator(s) ensure safe synchronization with facility power systems before connection
Interlocking: Kirk Key or mechanical walking-beam interlocks available to prevent cross-connection and ensure safe transfer sequences between utility and generator power
Connector Safety: Design supports compliance with NEC 406.13 for Single-Pole Separable Interconnects (Cam-Locks), preventing accidental disconnection under load
Dead-Front Design: Internal barriers prevent accidental contact with live busbars during operation or maintenance
Grounding: Dedicated grounding studs and fully rated ground bus ensure personnel safety during temporary power setup
VIDEO
BUILT THE CODI WAY
STRUCTURAL ENGINEERING
-
Hex-Formed Corners
-
Powder coating in any color
-
Internal cable routing pathways
-
Tab & slot nest together precisely
MANUFACTURING EXCELLENCE
-
Shorter lead-times than national OEMs
-
Ships right the first time
-
30 years of fabrication experience
-
100k sq.ft. Littleton, CO facility
OEM BREAKER FLEXIBILITY
-
Matches your existing infrastructure specs
-
No proprietary lock-in
-
Access to multiple OEM breaker brands
STREAMLINED ORDER PROCESS
-
Online configuration tool
-
Quotes reviewed in-house typically within 1 business day