UL 891 GENERATOR DOCKING STATIONS
Temporary Generator Connection
Provides safe, temporary generator connections for commercial, industrial, and critical facilities.
The CODI Generator Docking Station is a UL 891-listed dead-front switchboard engineered as a permanent connection point for temporary generator access. Built for critical power projects, each unit is configured around the site’s voltage, amperage, available fault current, connection type, enclosure rating, interlocking, metering, and project-specific safety options. Designed and assembled in Littleton, Colorado.
10-12
WEEK LEAD TIME
COMPLIANCE
UL 891: Dead-Front Switchboards.
NFPA 70 (NEC) Article 408: Compliant for Switchboard construction and wire bending space.
NEC 700.3(F), 2023 NEC: Supports permanent switching means for connecting a portable or temporary alternate power source during maintenance of the emergency source, subject to system design, installation, and AHJ approval.
NEC 406.13: Design supports safe use of Single-Pole Separable Interconnects (Cam-Locks).
Service Entrance (SE): Suitable for use as Service Equipment when specified and marked (per NEC 230).
NFPA 110 Testing Support: Configurations can include dedicated load-bank connections that support emergency power system testing under NFPA 110 Chapter 8, subject to system design and AHJ requirements.
RATINGS
Voltage: Configurable for 208Y/120V, 480Y/277V, and 600V 3-Phase AC systems.
Ampacity: Available in continuous current ratings from 400A to 4000A.
Short Circuit Current Rating (SCCR): Standard 65 kA SCCR; configurations available up to 100 kA rms symmetrical, subject to voltage and equipment configuration.
Environmental: TYPE 3R (Outdoor) rating standard for protection against rain, sleet, and snow; Type 3RX Stainless Steel available for corrosive environments .
Service Entrance: Optional Service Entrance (SE) rating allows the unit to serve as the primary disconnect point (per NEC 230).
CONSTRUCTION/BUILD
Construction: UL 891 dead-front construction.
Enclosure: Galvannealed steel with powder-coat or stainless steel finish.
Rating: NEMA 1 (indoor) and NEMA 3R (outdoor).
Seismic: Available with bracing to meet project-specific requirements per IBC 1613 and ASCE 7.
Mounting: Free-standing or wall-mount configurations available depending on ampacity and breaker frame size.
Access: Padlockable front doors with three-point latching.
Cable Entry: Removable gland plates and bottom-feed provisions for conduit routing and cable termination.
Bus: High-conductivity silver-plated copper or tin-plated aluminum; full-capacity neutral where required and an equipment-grounding bus sized for the application.
COMPONENTS
Connection Type: Industry-standard Series 16 Cam-Lock receptacles (color-coded for phase and conductor identification and labeled for system voltage and current rating) for rapid, tool-free generator cabling deployment.
Circuit Breakers: Available with qualified breaker families from multiple major manufacturers (Eaton, Siemens, ABB, etc.), subject to ratings and UL 891 construction requirements.
Surge Protection: Integrated Type 1 or Type 2 Surge Protective Devices (SPD) available to shield sensitive downstream electronics from transient voltage spikes.
Instrumentation: Phase-sequence monitoring verifies correct phase rotation before connection or energization. Optional voltage indicators provide visual source-voltage confirmation.
SAFETY
Interlocking: Kirk Key or mechanical walking-beam interlocks available to prevent cross-connection and ensure safe transfer sequences between utility and generator power.
Connector Safety: Design supports compliance with NEC 406.13 for Single-Pole Separable Interconnects (Cam-Locks), preventing accidental disconnection under load.
Dead-Front Construction: Barriers and covers limit access to energized parts during normal operation with doors and covers properly secured.
Grounding: Dedicated grounding studs and an equipment-grounding bus, sized for the application, provide a defined equipment-grounding path during temporary power setup.
BUILT THE CODI WAY
ENGINEERED
TO ORDER

In-house electrical and mechanical engineering
MANUFACTURING EXCELLENCE

100,000 sq. ft. Colorado manufacturing facility
RAPID ORDER PROCESSING
%2003-13-2026%20(15)%20200%20mm%201-200%20sec%20at%20f%20-%202_edited.jpg)
Direct access to the team reviewing, quoting and building your equipment.
BUILT TO YOUR SPECS IN THE USA

OEM-agnostic configurations. Built to your specifications. American manufacturing.
KEY FEATURES
Multi-OEM Breaker Options
Available with qualified circuit-breaker families from Eaton, Siemens, ABB, LS, and other manufacturers, subject to electrical ratings and UL 891 construction requirements.
Rapid Deployment
Features industry-standard Cam-Lock connectors for rapid, color-coded temporary generator connections during outages and planned maintenance.
UL 891 Listed Construction
Built to UL 891 Dead-Front Switchboard standards, ensuring a safe, serviceable, and code-compliant connection point.
Phase Sequence Verification
Phase-sequence monitoring verifies correct phase rotation before connection or energization.
Rugged Construction
Available in Type 1 indoor, Type 3R outdoor, and stainless steel Type 3R configurations for improved corrosion resistance.
Safety Interlocking
Options for Kirk Key or mechanical interlocks to prevent cross-connection and ensure safe transfer sequences between utility and generator power.
FAQ
What is a generator docking station?
A generator docking station is a permanently installed, UL 891-listed dead-front switchboard that provides a safe, code-compliant connection point for temporary generator power. It eliminates improvised cabling during outages by giving facilities a dedicated, pre-engineered interface between their electrical system and a portable or rental generator.
What electrical codes does the CODI Generator Docking Station comply with?
The CODI Generator Docking Station is UL 891 listed for dead-front switchboard construction and can be configured to support applicable NEC requirements, including Article 408 and temporary alternate-source connections under NEC 700.3(F) of the 2023 NEC. Final compliance depends on the adopted code edition, system design, installation, and AHJ approval.
What voltage and ampacity configurations are available?
Units are configurable for 208Y/120V, 480Y/277V, and 600V three-phase AC systems. Continuous current ratings are available from 400A to 4000A. Short circuit current ratings (SCCR) starts at 65 kA rms symmetrical, with configurations available up to 100 kA (SCCR).
Can the generator docking station be used for load bank testing?
Yes. CODI builds dual-purpose generator that facilitates testing performed as part of an NFPA 110 inspection, maintenance and testing program. These combined units allow critical facilities, such as hospitals and data centers, to perform mandatory routine load testing on permanent standby generators and safely connect temporary backup power using the same UL 891-listed enclosure.
What enclosure options are available for outdoor installation?
The standard outdoor configuration is NEMA 3R (Type 3R), rated for protection against rain, sleet, and snow. A stainless steel Type 3R enclosure is available for additional corrosive resistance. Indoor installations use a NEMA 1 (Type 1) enclosure. All configurations use padlockable front doors with three-point latching.
SEE. BUILD. TALK.
SEE SINGLE-LINE DIAGRAMS (SLS)
SEE generator docking station topologies: UL 891 bus routing, breaker interlocks, and cam-lock inputs. Review these one-line schematics to verify site electrical architecture before committing to a build.