UL 891 GENERATOR DOCKING STATIONS

Temporary Generator Connection

Provides safe, temporary generator connections for commercial, industrial, and critical facilities.

The CODI Generator Docking Station is a UL 891-listed dead-front switchboard engineered as a permanent connection point for temporary generator access. Built for critical power projects, each unit is configured around the site’s voltage, amperage, available fault current, connection type, enclosure rating, interlocking, metering, and project-specific safety options. Designed and assembled in Littleton, Colorado.


10-12

WEEK LEAD TIME

SPECIFICATIONS

Specs At A Glance

  • Standard UL 891 Listed
  • Ampacity 400A–4000A
  • Voltage 208Y/120V–600V, 3-phase
  • SCCR 65–100
  • Enclosures Type 1 / 3R / stainless steel 3R

Full Specifications

Power Controls Glossary

COMPLIANCE

  • UL 891: Dead-Front Switchboards. 

  • NFPA 70 (NEC) Article 408: Compliant for Switchboard construction and wire bending space.

  • NEC 700.3(F), 2023 NEC: Supports permanent switching means for connecting a portable or temporary alternate power source during maintenance of the emergency source, subject to system design, installation, and AHJ approval.

  • NEC 406.13: Design supports safe use of Single-Pole Separable Interconnects (Cam-Locks).

  • Service Entrance (SE): Suitable for use as Service Equipment when specified and marked (per NEC 230).

  • NFPA 110 Testing Support: Configurations can include dedicated load-bank connections that support emergency power system testing under NFPA 110 Chapter 8, subject to system design and AHJ requirements.

RATINGS

  • Voltage: Configurable for 208Y/120V, 480Y/277V, and 600V 3-Phase AC systems.

  • Ampacity: Available in continuous current ratings from 400A to 4000A.

  • Short Circuit Current Rating (SCCR): Standard 65 kA SCCR; configurations available up to 100 kA rms symmetrical, subject to voltage and equipment configuration.

  • Environmental: TYPE 3R (Outdoor) rating standard for protection against rain, sleet, and snow; Type 3RX Stainless Steel available for corrosive environments .

  • Service Entrance: Optional Service Entrance (SE) rating allows the unit to serve as the primary disconnect point (per NEC 230).

CONSTRUCTION/BUILD

  • Construction: UL 891 dead-front construction.

  • Enclosure: Galvannealed steel with powder-coat or stainless steel finish.

  • Rating: NEMA 1 (indoor) and NEMA 3R (outdoor).

  • Seismic: Available with bracing to meet project-specific requirements per IBC 1613 and ASCE 7.

  • Mounting: Free-standing or wall-mount configurations available depending on ampacity and breaker frame size.

  • Access: Padlockable front doors with three-point latching.

  • Cable Entry: Removable gland plates and bottom-feed provisions for conduit routing and cable termination.

  • Bus: High-conductivity silver-plated copper or tin-plated aluminum; full-capacity neutral where required and an equipment-grounding bus sized for the application.

COMPONENTS

  • Connection Type: Industry-standard Series 16 Cam-Lock receptacles (color-coded for phase and conductor identification and labeled for system voltage and current rating) for rapid, tool-free generator cabling deployment.

  • Circuit Breakers: Available with qualified breaker families from multiple major manufacturers (Eaton, Siemens, ABB, etc.), subject to ratings and UL 891 construction requirements.

  • Surge Protection: Integrated Type 1 or Type 2 Surge Protective Devices (SPD) available to shield sensitive downstream electronics from transient voltage spikes.

  • Instrumentation: Phase-sequence monitoring verifies correct phase rotation before connection or energization. Optional voltage indicators provide visual source-voltage confirmation.

SAFETY

  • Interlocking: Kirk Key or mechanical walking-beam interlocks available to prevent cross-connection and ensure safe transfer sequences between utility and generator power.

  • Connector Safety: Design supports compliance with NEC 406.13 for Single-Pole Separable Interconnects (Cam-Locks), preventing accidental disconnection under load.

  • Dead-Front Construction: Barriers and covers limit access to energized parts during normal operation with doors and covers properly secured.

  • Grounding: Dedicated grounding studs and an equipment-grounding bus, sized for the application, provide a defined equipment-grounding path during temporary power setup.


BUILT THE CODI WAY

 ENGINEERED
TO ORDER

CODI Building a panelboard in our Colorado Shop

In-house electrical and mechanical engineering

MANUFACTURING EXCELLENCE

CODI's proprietary Hex Frame

100,000 sq. ft. Colorado manufacturing facility

RAPID ORDER PROCESSING

CODI Engineer after switchboard build

Direct access to the team reviewing, quoting and building your equipment.

BUILT TO YOUR SPECS IN THE USA

Switchboards made in USA

OEM-agnostic configurations. Built to your specifications. American manufacturing.

KEY FEATURES

Multi-OEM Breaker Options

Available with qualified circuit-breaker families from Eaton, Siemens, ABB, LS, and other manufacturers, subject to electrical ratings and UL 891 construction requirements.

Rapid Deployment

Features industry-standard Cam-Lock connectors for rapid, color-coded temporary generator connections during outages and planned maintenance.

UL 891 Listed Construction

Built to UL 891 Dead-Front Switchboard standards, ensuring a safe, serviceable, and code-compliant connection point.

Phase Sequence Verification

Phase-sequence monitoring verifies correct phase rotation before connection or energization.

Rugged Construction

Available in Type 1 indoor, Type 3R outdoor, and stainless steel Type 3R configurations for improved corrosion resistance.

Safety Interlocking

Options for Kirk Key or mechanical interlocks to prevent cross-connection and ensure safe transfer sequences between utility and generator power.

FAQ

What is a generator docking station?

A generator docking station is a permanently installed, UL 891-listed dead-front switchboard that provides a safe, code-compliant connection point for temporary generator power. It eliminates improvised cabling during outages by giving facilities a dedicated, pre-engineered interface between their electrical system and a portable or rental generator.

What electrical codes does the CODI Generator Docking Station comply with?

The CODI Generator Docking Station is UL 891 listed for dead-front switchboard construction and can be configured to support applicable NEC requirements, including Article 408 and temporary alternate-source connections under NEC 700.3(F) of the 2023 NEC. Final compliance depends on the adopted code edition, system design, installation, and AHJ approval.

What voltage and ampacity configurations are available?

Units are configurable for 208Y/120V, 480Y/277V, and 600V three-phase AC systems. Continuous current ratings are available from 400A to 4000A. Short circuit current ratings (SCCR) starts at 65 kA rms symmetrical, with configurations available up to 100 kA (SCCR).

Can the generator docking station be used for load bank testing?

Yes. CODI builds dual-purpose generator that facilitates testing performed as part of an NFPA 110 inspection, maintenance and testing program. These combined units allow critical facilities, such as hospitals and data centers, to perform mandatory routine load testing on permanent standby generators and safely connect temporary backup power using the same UL 891-listed enclosure.

What enclosure options are available for outdoor installation?

The standard outdoor configuration is NEMA 3R (Type 3R), rated for protection against rain, sleet, and snow. A stainless steel Type 3R enclosure is available for additional corrosive resistance. Indoor installations use a NEMA 1 (Type 1) enclosure. All configurations use padlockable front doors with three-point latching.

SEE. BUILD. TALK.

SEE SINGLE-LINE DIAGRAMS (SLS)

SEE generator docking station topologies: UL 891 bus routing, breaker interlocks, and cam-lock inputs.  Review these one-line schematics to verify site electrical architecture before committing to a build.

Topology Page

BUILD TO SPECS

BUILD to specs : ratings, enclosure, bus, and connection options, assembled into a unit matched to your project requirements. This information is what we use to provide a budgetary quote.

Configuration Page

CONNECT WITH ENGINEERING

TALK with a CODI engineer who knows power controls, your application, and your constraints. Share the details, and we’ll tell you directly whether CODI has a solution that fits.

Senior Engineer

SWITCHBOARDS

Low-voltage UL 891 dead-front electrical switchboard lineup

Manages service-entrance and main power distribution for industrial and critical facilities.

VIEW PRODUCT

PANELBOARDS

UL 67 low-voltage branch-circuit electrical distribution panelboard

Distributes branch-circuit power throughout commercial, institutional, and industrial facilities.

VIEW PRODUCT

RELATED PRODUCTS

bottom of page