Low-Voltage UL 67
PANELBOARDS
Distributes branch-circuit power throughout commercial, institutional, and industrial facilities.
CODI builds custom UL 67 listed panelboards for commercial, institutional, data center, and light industrial power distribution. Available in main lugs only or main circuit breaker configurations, each panelboard is built around your voltage, circuit count, enclosure rating, and preferred breaker manufacturer.
Manufactured in Littleton, Colorado, CODI panelboards give facility teams a configurable alternative to catalog-only equipment, with clean documentation, shorter lead times, and no proprietary breaker lock-in.
10-12
WEEK LEAD TIME
BUILT THE CODI WAY
STRUCTURAL ENGINEERING

In-house electrical and mechanical engineering
MANUFACTURING EXCELLENCE

100,000 sq. ft. Colorado manufacturing facility
RAPID ORDER PROCESSING
%2003-13-2026%20(15)%20200%20mm%201-200%20sec%20at%20f%20-%202_edited.jpg)
Direct access to the team reviewing, quoting and building your equipment.
BUILT TO YOUR SPECS IN THE USA

OEM-agnostic configurations. Built to your specifications. American manufacturing.
COMPLIANCE
UL 67: Panelboards
NFPA 70 (NEC) Article 408: Compliant for Panelboard construction and wire bending space
NEC 408.36: Overcurrent protection requirements for panelboards
NEC 230.70 / 230.91: Service equipment requirements when configured as service entrance
Service Entrance (SE): Suitable for use as service equipment when specified per NEC 230
RATINGS
Voltage: 120/208V, 277/480V, up to 600V; single-phase and three-phase configurations available
Ampacity: Main ratings from 100A to 1200A
Short-Circuit Current Rating (SCCR): Standard 65kAIC; higher ratings available with current-limiting fuses or high-SCCR breakers
Phases: 1-phase 2-wire; 1-phase 3-wire; 3-phase 3-wire; 3-phase 4-wire
Branch Circuits: Up to 42 circuits standard; higher counts available
CONSTRUCTION/BUILD
Enclosure Material: Heavy-gauge steel with powder-coat finish
Bus: Silver-plated copper main and distribution bus; fully-rated bus standard
Main Device: Main lugs only (MLO) or main circuit breaker (MCB) configurations available
Branch Spaces: Top-feed or bottom-feed provisions; surface or flush-mount options
Finish: Powder-coated standard; custom colors available
COMPONENTS
Main Protective Device: Molded-case circuit breaker or main lugs per specification
Branch Breakers: 1-pole, 2-pole, or 3-pole circuit breakers from major manufacturers (Siemens, Eaton, etc.)
Neutral Bar: Full-capacity silver-plated neutral bar with individual terminal lugs
Ground Bar: Isolated or bonded ground bar as required by application
Surge Protection: Type 1 or Type 2 SPD available for downstream electronics protection
SAFETY
Dead-Front Design: Interior dead-front panel prevents accidental contact with live bus and breakers during operation
Grounding: Dedicated ground bus bonded to enclosure per NEC requirements
Overcurrent Protection: Branch circuit breakers provide coordinated short-circuit and overload protection
Arc-Flash: Panelboard configuration and documentation support arc-flash analysis per NFPA 70E
Locking: Panelboard cover latch and optional padlockable trim for secured access
KEY FEATURES
Custom-Configured Not Catalog
Built to your exact circuit count, voltage, and enclosure rating rather than forcing a standard catalog size that leaves capacity unused or falls short.
Multi-Brand Breaker Flexibility
Accepts branch breakers from Siemens, Eaton, ABB, Schneider Electric, and LS Electric to match your facility standard or existing infrastructure.
UL 67 Listed
Factory-tested and UL 67 listed. Ships with a complete documentation package including wiring diagrams, BOM, and UL label.
Full NEMA Enclosure Range
Available in indoor, outdoor, washdown, and corrosive environment requirements (NEMA 1, 3R, 4, and 4X).
Colorado Built — Shorter Lead Times
Manufactured in Littleton, CO with 30+ years of fabrication experience. Custom configurations without the lead times of national OEMs.
No Proprietary Lock-In
You specify the breaker brand at the time of order. No forced substitutions and no downstream service dependency on a single manufacturer.
FAQ
What is the difference between a main lugs only (MLO) and main circuit breaker (MCB) panelboard?
An MLO panelboard has no main overcurrent device — the incoming conductors terminate directly on the main lugs, and overcurrent protection must be provided upstream. An MCB panelboard includes a main circuit breaker that serves as both the disconnect and the primary overcurrent protection for all branch circuits. CODI builds both configurations; the right choice depends on where overcurrent protection is located in your distribution system and whether the panelboard will serve as the service entrance.
What breaker brands does CODI support in its panelboards?
CODI panelboards accept branch circuit breakers from Eaton, Siemens, ABB, LS Electric, and Schneider Electric. You specify the breaker manufacturer at the time of order to match your facility standard or existing infrastructure. There is no proprietary breaker requirement and no downstream service dependency on a single manufacturer.
Can a CODI panelboard be configured for outdoor installation?
Yes. CODI panelboards are available in NEMA 1 (indoor), NEMA 3R (outdoor, rain and sleet rated), NEMA 4 (watertight), and NEMA 4X (corrosion-resistant) enclosure ratings. Outdoor and washdown applications are standard configurations, not special orders.
SEE. BUILD. TALK.
CONFIGURE walks you through the build: ratings, enclosure, bus, and connection options, assembled into a unit matched to your project.
This information is what we use to provide a budgetary quote.
Build your spec

CONNECT puts you in touch with a CODI engineer who knows power controls products, not someone working from a script.
Tell them your application and your constraints, and you get a straight answer on whether we have something that solves it.