top of page
CODI, Power Controls  White Subtext 6-3-2026.png

Low-Voltage UL 891 Switchboards

SWITCHBOARDS

Engineer-to-order dead-front switchboards for service entrance, main distribution, and emergency power applications.

CODI builds custom UL 891 listed switchboards for service entrance, main distribution, emergency power, and commercial power distribution applications. Each dead-front switchboard is engineered around your voltage, ampacity, fault current, breaker standard, enclosure rating, and site-specific requirements.


Manufactured in Littleton, Colorado, CODI switchboards give facility teams a configurable alternative to catalog-only equipment, with clean documentation, multi-brand breaker flexibility, and shorter lead times than traditional national OEM channels.

400A–5000A

120/208V–347/600V

65-200kAIC

KEY FEATURES

Custom Configuration

Engineered to your project's exact voltage, ampacity, fault current, and breaker requirements — not a catalog solution.

UL 891 Listed Dead-Front

Every switchboard ships UL 891 listed as a dead-front assembly, preventing access to live bus and components during normal operation.

High-Capacity Bus

Main bus ratings from 400A to 5000A; silver-plated copper or tin-plated aluminum bus available.

High Fault Current Ratings

Short-Circuit Current Ratings (SCCR) 65kAIC standard up to 200kAIC to match facility fault current requirements.

Multi-Brand Breaker Compatibility

Accommodates molded-case and insulated-case circuit breakers from major manufacturers (Siemens, Eaton, ABB, etc.) — no proprietary lock-in.

Enclosure Options

TYPE 1 (indoor) and TYPE 3R (outdoor) configurations; stainless steel available for corrosive environments.

FULL SPECIFICATIONS

    • Applicable Standard: UL 891 – Dead-Front Switchboards 

    • Applicable Codes: NEC (ANSI/NFPA 70); CSA C22.2 No. 244 (Canada, when applicable) 

    • Maximum Voltage Rating: Up to 600 V AC nominal (maximum 1,000 V within UL scope) 

    • Intended Application: Commercial and Light Industrial Power Distribution

    • Voltage: Configurable for 208Y/120V, 480Y/277V, and 600V 3-Phase AC systems

    • Ampacity: Available in continuous current ratings from 400A to 4000A

    • Short Circuit Current Rating (SCCR): Standard 65kAIC bracing; options available up to 100kAIC to match facility fault current requirements

    • Environmental: TYPE 3R (Outdoor) rating standard for protection against rain, sleet, and snow; Stainless Steel available for corrosive environments

    • Service Entrance: Optional Service Entrance (SE) rating allows the unit to serve as the primary disconnect point (per NEC 230)

    • Construction: Dead-front per UL 891

    • Enclosure: Galvannealed steel with powder-coat or stainless steel finish

    • Rating: NEMA 1 (indoor) and NEMA 3R (outdoor)

    • Seismic: Available with bracing to meet project-specific requirements per IBC 1613 and ASCE 7

    • Mounting: Free-standing configurations standard; wall-mount availability dependent on ampacity and breaker frame size

    • Access: Padlockable front doors with three-point latching

    • Cable Entry: Removable gland plates and bottom-feed provisions for conduit routing and cable termination

    • Bus: High-conductivity silver-plated copper or tin-plated aluminum; fully rated neutral and ground bus options available

    • Connection Type: Industry-standard Series 16 Cam-Lock receptacles (color-coded to voltage) for rapid, tool-free generator cabling deployment

    • Circuit Breakers: Universal design accommodates power breakers from major manufacturers (Eaton, Siemens, ABB, etc.) to match existing site standards

    • Surge Protection: Integrated Type 1 or Type 2 Surge Protective Devices (SPD) available to shield sensitive downstream electronics from transient voltage spikes

    • Instrumentation: Phase Rotation Monitor and optional Voltage Indicator(s) ensure safe synchronization with facility power systems before connection

    • SCCR: Rated and marked per UL 891 to project-specific short circuit current requirements

    • Trip Settings: LSI and LSIG configurations available

    • Arc-Flash Risk Reduction: Energy-reducing maintenance settings per NFPA 70 240.87; compatible with AERMS, DAS (Siemens), and RELT (ABB)

    • Zone-Selective Interlocking: Available where applicable

    • Ground Fault Protection: Per NFPA 70B

    • Thermal Inspection: Compliance-ready designs for routine infrared inspection

10-12

WEEK LEAD TIME

RESOURCES

Add a Title
Add a Title
Add a Title

VIDEO

BUILT THE CODI WAY

STRUCTURAL ENGINEERING

  • Hex-Formed Corners

  • Powder coating in any color

  • Internal cable routing pathways

  • Tab & slot nest together precisely

MANUFACTURING EXCELLENCE

  • Shorter lead-times than national OEMs

  • Ships right the first time

  • 30 years of fabrication experience

  • 100k sq.ft. Littleton, CO facility

OEM BREAKER FLEXIBILITY

  • Matches your existing infrastructure specs

  • No proprietary lock-in

  • Access to multiple OEM breaker brands

STREAMLINED ORDER PROCESS

  • Online configuration tool

  • Quotes reviewed in-house typically within 1 business day 

READY TO RECEIVE YOUR QUOTE? 

bottom of page